embolism coil Search Results


90
MicroVention terumo coil embolization with overlapping low-profile visualized intraluminal support (lvis) stents
Coil Embolization With Overlapping Low Profile Visualized Intraluminal Support (Lvis) Stents, supplied by MicroVention terumo, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/embolism+coil/pmc07162815-16-12-22?v=MicroVention+terumo
Average 90 stars, based on 1 article reviews
coil embolization with overlapping low-profile visualized intraluminal support (lvis) stents - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

90
Yodogawa Hu Tech Co Ltd coil embolization
Coil Embolization, supplied by Yodogawa Hu Tech Co Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/embolism+coil/10__5797_slash_jnet__cr__2017___0117-25-24-29?v=Yodogawa+Hu+Tech+Co+Ltd
Average 90 stars, based on 1 article reviews
coil embolization - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

90
SAS institute coil embolization of
Overall demographic, clinical, and instrumental data and outcomes according to the age of patients at diagnosis of a series of patients with a diagnosis of scimitar syndrome (n = 485)
Coil Embolization Of, supplied by SAS institute, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/embolism+coil/pmc08288726-52-0-3?v=SAS+institute
Average 90 stars, based on 1 article reviews
coil embolization of - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

90
NeuroInterventions Inc coil embolization
Female patient with an incidental right supraophthalmic internal carotid artery aneurysm. a Planning 3D-rotational angiogram demonstrated the wide-necked aneurysm on the posterior ICA wall with an acute angle between the aneurysm neck and the parent artery creating a ledge. b A Synchro 0.014in. microwire ( white dashed arrow ) was navigated across the aneurysm; however, due to the off-set between the 0.027in. microcatheter and the microwire the tip of the microcatheter ( black arrow ) was stuck on the ledge ( white arrow ) between the aneurysm neck and the parent artery preventing to be advanced distally. c , d An X‑pedion 0.010in. (Medtronic, Minneapolis, MN, USA) microwire ( black dashed arrow ) was then introduced into the Phenom 0.027in. parallel to the Synchro 0.014in. and provided the necessary support for the microcatheter to be advanced past the aneurysm and positioned distally. e , f A 4.75 × 18 mm Pipeline Flex <t>embolization</t> device (Medtronic, Minneapolis, MN, USA) was subsequently deployed. The cone beam CT demonstrated a good wall apposition
Coil Embolization, supplied by NeuroInterventions Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/embolism+coil/pmc09187555-107-13-6?v=NeuroInterventions+Inc
Average 90 stars, based on 1 article reviews
coil embolization - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

90
Georg Thieme Verlag KG video 1 endoscopic coil embolization of major intrahepatic biliary leak after partial hepatectomy
Female patient with an incidental right supraophthalmic internal carotid artery aneurysm. a Planning 3D-rotational angiogram demonstrated the wide-necked aneurysm on the posterior ICA wall with an acute angle between the aneurysm neck and the parent artery creating a ledge. b A Synchro 0.014in. microwire ( white dashed arrow ) was navigated across the aneurysm; however, due to the off-set between the 0.027in. microcatheter and the microwire the tip of the microcatheter ( black arrow ) was stuck on the ledge ( white arrow ) between the aneurysm neck and the parent artery preventing to be advanced distally. c , d An X‑pedion 0.010in. (Medtronic, Minneapolis, MN, USA) microwire ( black dashed arrow ) was then introduced into the Phenom 0.027in. parallel to the Synchro 0.014in. and provided the necessary support for the microcatheter to be advanced past the aneurysm and positioned distally. e , f A 4.75 × 18 mm Pipeline Flex <t>embolization</t> device (Medtronic, Minneapolis, MN, USA) was subsequently deployed. The cone beam CT demonstrated a good wall apposition
Video 1 Endoscopic Coil Embolization Of Major Intrahepatic Biliary Leak After Partial Hepatectomy, supplied by Georg Thieme Verlag KG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/embolism+coil/pm32131087-55-36-14?v=Georg+Thieme+Verlag+KG
Average 90 stars, based on 1 article reviews
video 1 endoscopic coil embolization of major intrahepatic biliary leak after partial hepatectomy - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

90
Georg Thieme Verlag KG video 2 angiography and coil embolization of branches supplying a duodenal arteriovenous malformation
Female patient with an incidental right supraophthalmic internal carotid artery aneurysm. a Planning 3D-rotational angiogram demonstrated the wide-necked aneurysm on the posterior ICA wall with an acute angle between the aneurysm neck and the parent artery creating a ledge. b A Synchro 0.014in. microwire ( white dashed arrow ) was navigated across the aneurysm; however, due to the off-set between the 0.027in. microcatheter and the microwire the tip of the microcatheter ( black arrow ) was stuck on the ledge ( white arrow ) between the aneurysm neck and the parent artery preventing to be advanced distally. c , d An X‑pedion 0.010in. (Medtronic, Minneapolis, MN, USA) microwire ( black dashed arrow ) was then introduced into the Phenom 0.027in. parallel to the Synchro 0.014in. and provided the necessary support for the microcatheter to be advanced past the aneurysm and positioned distally. e , f A 4.75 × 18 mm Pipeline Flex <t>embolization</t> device (Medtronic, Minneapolis, MN, USA) was subsequently deployed. The cone beam CT demonstrated a good wall apposition
Video 2 Angiography And Coil Embolization Of Branches Supplying A Duodenal Arteriovenous Malformation, supplied by Georg Thieme Verlag KG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/embolism+coil/pm27875847-48-50-16?v=Georg+Thieme+Verlag+KG
Average 90 stars, based on 1 article reviews
video 2 angiography and coil embolization of branches supplying a duodenal arteriovenous malformation - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

90
MicroPort Scientific Corporation numen coil embolization system
Female patient with an incidental right supraophthalmic internal carotid artery aneurysm. a Planning 3D-rotational angiogram demonstrated the wide-necked aneurysm on the posterior ICA wall with an acute angle between the aneurysm neck and the parent artery creating a ledge. b A Synchro 0.014in. microwire ( white dashed arrow ) was navigated across the aneurysm; however, due to the off-set between the 0.027in. microcatheter and the microwire the tip of the microcatheter ( black arrow ) was stuck on the ledge ( white arrow ) between the aneurysm neck and the parent artery preventing to be advanced distally. c , d An X‑pedion 0.010in. (Medtronic, Minneapolis, MN, USA) microwire ( black dashed arrow ) was then introduced into the Phenom 0.027in. parallel to the Synchro 0.014in. and provided the necessary support for the microcatheter to be advanced past the aneurysm and positioned distally. e , f A 4.75 × 18 mm Pipeline Flex <t>embolization</t> device (Medtronic, Minneapolis, MN, USA) was subsequently deployed. The cone beam CT demonstrated a good wall apposition
Numen Coil Embolization System, supplied by MicroPort Scientific Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/embolism+coil/pm37328839-49-27-31?v=MicroPort+Scientific+Corporation
Average 90 stars, based on 1 article reviews
numen coil embolization system - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

90
Blockade Medical microcoils barricade helical fill endovascular embolization coil
Female patient with an incidental right supraophthalmic internal carotid artery aneurysm. a Planning 3D-rotational angiogram demonstrated the wide-necked aneurysm on the posterior ICA wall with an acute angle between the aneurysm neck and the parent artery creating a ledge. b A Synchro 0.014in. microwire ( white dashed arrow ) was navigated across the aneurysm; however, due to the off-set between the 0.027in. microcatheter and the microwire the tip of the microcatheter ( black arrow ) was stuck on the ledge ( white arrow ) between the aneurysm neck and the parent artery preventing to be advanced distally. c , d An X‑pedion 0.010in. (Medtronic, Minneapolis, MN, USA) microwire ( black dashed arrow ) was then introduced into the Phenom 0.027in. parallel to the Synchro 0.014in. and provided the necessary support for the microcatheter to be advanced past the aneurysm and positioned distally. e , f A 4.75 × 18 mm Pipeline Flex <t>embolization</t> device (Medtronic, Minneapolis, MN, USA) was subsequently deployed. The cone beam CT demonstrated a good wall apposition
Microcoils Barricade Helical Fill Endovascular Embolization Coil, supplied by Blockade Medical, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/embolism+coil/pmc04199465-22-34-43?v=Blockade+Medical
Average 90 stars, based on 1 article reviews
microcoils barricade helical fill endovascular embolization coil - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

90
MicroVention terumo hydrogel embolic system (hes) coil
Female patient with an incidental right supraophthalmic internal carotid artery aneurysm. a Planning 3D-rotational angiogram demonstrated the wide-necked aneurysm on the posterior ICA wall with an acute angle between the aneurysm neck and the parent artery creating a ledge. b A Synchro 0.014in. microwire ( white dashed arrow ) was navigated across the aneurysm; however, due to the off-set between the 0.027in. microcatheter and the microwire the tip of the microcatheter ( black arrow ) was stuck on the ledge ( white arrow ) between the aneurysm neck and the parent artery preventing to be advanced distally. c , d An X‑pedion 0.010in. (Medtronic, Minneapolis, MN, USA) microwire ( black dashed arrow ) was then introduced into the Phenom 0.027in. parallel to the Synchro 0.014in. and provided the necessary support for the microcatheter to be advanced past the aneurysm and positioned distally. e , f A 4.75 × 18 mm Pipeline Flex <t>embolization</t> device (Medtronic, Minneapolis, MN, USA) was subsequently deployed. The cone beam CT demonstrated a good wall apposition
Hydrogel Embolic System (Hes) Coil, supplied by MicroVention terumo, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/embolism+coil/10__3171_slash_2019__7__jns__aans2019abstracts-337-2-7?v=MicroVention+terumo
Average 90 stars, based on 1 article reviews
hydrogel embolic system (hes) coil - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

90
Verlag GmbH detachable coil embolization
Female patient with an incidental right supraophthalmic internal carotid artery aneurysm. a Planning 3D-rotational angiogram demonstrated the wide-necked aneurysm on the posterior ICA wall with an acute angle between the aneurysm neck and the parent artery creating a ledge. b A Synchro 0.014in. microwire ( white dashed arrow ) was navigated across the aneurysm; however, due to the off-set between the 0.027in. microcatheter and the microwire the tip of the microcatheter ( black arrow ) was stuck on the ledge ( white arrow ) between the aneurysm neck and the parent artery preventing to be advanced distally. c , d An X‑pedion 0.010in. (Medtronic, Minneapolis, MN, USA) microwire ( black dashed arrow ) was then introduced into the Phenom 0.027in. parallel to the Synchro 0.014in. and provided the necessary support for the microcatheter to be advanced past the aneurysm and positioned distally. e , f A 4.75 × 18 mm Pipeline Flex <t>embolization</t> device (Medtronic, Minneapolis, MN, USA) was subsequently deployed. The cone beam CT demonstrated a good wall apposition
Detachable Coil Embolization, supplied by Verlag GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/embolism+coil/pm10234971-274-16-2?v=Verlag+GmbH
Average 90 stars, based on 1 article reviews
detachable coil embolization - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

90
MicroPort Scientific Corporation neurotech coil embolization system
Female patient with an incidental right supraophthalmic internal carotid artery aneurysm. a Planning 3D-rotational angiogram demonstrated the wide-necked aneurysm on the posterior ICA wall with an acute angle between the aneurysm neck and the parent artery creating a ledge. b A Synchro 0.014in. microwire ( white dashed arrow ) was navigated across the aneurysm; however, due to the off-set between the 0.027in. microcatheter and the microwire the tip of the microcatheter ( black arrow ) was stuck on the ledge ( white arrow ) between the aneurysm neck and the parent artery preventing to be advanced distally. c , d An X‑pedion 0.010in. (Medtronic, Minneapolis, MN, USA) microwire ( black dashed arrow ) was then introduced into the Phenom 0.027in. parallel to the Synchro 0.014in. and provided the necessary support for the microcatheter to be advanced past the aneurysm and positioned distally. e , f A 4.75 × 18 mm Pipeline Flex <t>embolization</t> device (Medtronic, Minneapolis, MN, USA) was subsequently deployed. The cone beam CT demonstrated a good wall apposition
Neurotech Coil Embolization System, supplied by MicroPort Scientific Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/embolism+coil/nct02990156-17-5-4?v=MicroPort+Scientific+Corporation
Average 90 stars, based on 1 article reviews
neurotech coil embolization system - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

90
Surgical Associates Ltd coil embolization
Female patient with an incidental right supraophthalmic internal carotid artery aneurysm. a Planning 3D-rotational angiogram demonstrated the wide-necked aneurysm on the posterior ICA wall with an acute angle between the aneurysm neck and the parent artery creating a ledge. b A Synchro 0.014in. microwire ( white dashed arrow ) was navigated across the aneurysm; however, due to the off-set between the 0.027in. microcatheter and the microwire the tip of the microcatheter ( black arrow ) was stuck on the ledge ( white arrow ) between the aneurysm neck and the parent artery preventing to be advanced distally. c , d An X‑pedion 0.010in. (Medtronic, Minneapolis, MN, USA) microwire ( black dashed arrow ) was then introduced into the Phenom 0.027in. parallel to the Synchro 0.014in. and provided the necessary support for the microcatheter to be advanced past the aneurysm and positioned distally. e , f A 4.75 × 18 mm Pipeline Flex <t>embolization</t> device (Medtronic, Minneapolis, MN, USA) was subsequently deployed. The cone beam CT demonstrated a good wall apposition
Coil Embolization, supplied by Surgical Associates Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/embolism+coil/pm19059144-16-17-1?v=Surgical+Associates+Ltd
Average 90 stars, based on 1 article reviews
coil embolization - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

Image Search Results


Overall demographic, clinical, and instrumental data and outcomes according to the age of patients at diagnosis of a series of patients with a diagnosis of scimitar syndrome (n = 485)

Journal: JTCVS Techniques

Article Title: A sword threatening the heart: The scimitar syndrome

doi: 10.1016/j.xjtc.2020.01.017

Figure Lengend Snippet: Overall demographic, clinical, and instrumental data and outcomes according to the age of patients at diagnosis of a series of patients with a diagnosis of scimitar syndrome (n = 485)

Article Snippet: Coil embolization of SAS , 93/279 (33%).

Techniques: Biomarker Discovery, Isolation

Demographics and surgical data of a series of patients with scimitar syndrome undergoing surgery (n = 279)

Journal: JTCVS Techniques

Article Title: A sword threatening the heart: The scimitar syndrome

doi: 10.1016/j.xjtc.2020.01.017

Figure Lengend Snippet: Demographics and surgical data of a series of patients with scimitar syndrome undergoing surgery (n = 279)

Article Snippet: Coil embolization of SAS , 93/279 (33%).

Techniques: Biomarker Discovery, Medications

Female patient with an incidental right supraophthalmic internal carotid artery aneurysm. a Planning 3D-rotational angiogram demonstrated the wide-necked aneurysm on the posterior ICA wall with an acute angle between the aneurysm neck and the parent artery creating a ledge. b A Synchro 0.014in. microwire ( white dashed arrow ) was navigated across the aneurysm; however, due to the off-set between the 0.027in. microcatheter and the microwire the tip of the microcatheter ( black arrow ) was stuck on the ledge ( white arrow ) between the aneurysm neck and the parent artery preventing to be advanced distally. c , d An X‑pedion 0.010in. (Medtronic, Minneapolis, MN, USA) microwire ( black dashed arrow ) was then introduced into the Phenom 0.027in. parallel to the Synchro 0.014in. and provided the necessary support for the microcatheter to be advanced past the aneurysm and positioned distally. e , f A 4.75 × 18 mm Pipeline Flex embolization device (Medtronic, Minneapolis, MN, USA) was subsequently deployed. The cone beam CT demonstrated a good wall apposition

Journal: Clinical Neuroradiology

Article Title: When Two Is Better than One

doi: 10.1007/s00062-021-01053-x

Figure Lengend Snippet: Female patient with an incidental right supraophthalmic internal carotid artery aneurysm. a Planning 3D-rotational angiogram demonstrated the wide-necked aneurysm on the posterior ICA wall with an acute angle between the aneurysm neck and the parent artery creating a ledge. b A Synchro 0.014in. microwire ( white dashed arrow ) was navigated across the aneurysm; however, due to the off-set between the 0.027in. microcatheter and the microwire the tip of the microcatheter ( black arrow ) was stuck on the ledge ( white arrow ) between the aneurysm neck and the parent artery preventing to be advanced distally. c , d An X‑pedion 0.010in. (Medtronic, Minneapolis, MN, USA) microwire ( black dashed arrow ) was then introduced into the Phenom 0.027in. parallel to the Synchro 0.014in. and provided the necessary support for the microcatheter to be advanced past the aneurysm and positioned distally. e , f A 4.75 × 18 mm Pipeline Flex embolization device (Medtronic, Minneapolis, MN, USA) was subsequently deployed. The cone beam CT demonstrated a good wall apposition

Article Snippet: This technique has been reported in neurointerventions for vertebral artery origin stenting, or coil embolization of posterior circulation aneurysms in patients with proximal vessel tortuosity.

Techniques:

Female patient with a family history of aneurysmal subarachnoid hemorrhage and incidental left paraophthalmic internal carotid artery. a 3D angiogram demonstrates the wide-necked aneurysm just distal to the origin of the ophthalmic artery. b Attempts to navigate a Marksman microcatheter over a Synchro 0.014in. microwire positioned in the left M2 were unsuccessful with the catheter tip being caught on the ophthalmic artery origin ( white arrow ). Note, a second microcatheter with a wire ( black arrow ) is being advanced into the aneurysm which was later used for coiling. c Adding an X‑pedion 0.010in microwire ( black dashed arrow ) within the Marksman microcatheter, which was advanced similarly into the left M2, provided the necessary support for the microcatheter to traverse across the ophthalmic segment for distal positioning. d – f A 4.75 × 18 mm Pipeline Flex embolization device was subsequently deployed and the aneurysm was coiled

Journal: Clinical Neuroradiology

Article Title: When Two Is Better than One

doi: 10.1007/s00062-021-01053-x

Figure Lengend Snippet: Female patient with a family history of aneurysmal subarachnoid hemorrhage and incidental left paraophthalmic internal carotid artery. a 3D angiogram demonstrates the wide-necked aneurysm just distal to the origin of the ophthalmic artery. b Attempts to navigate a Marksman microcatheter over a Synchro 0.014in. microwire positioned in the left M2 were unsuccessful with the catheter tip being caught on the ophthalmic artery origin ( white arrow ). Note, a second microcatheter with a wire ( black arrow ) is being advanced into the aneurysm which was later used for coiling. c Adding an X‑pedion 0.010in microwire ( black dashed arrow ) within the Marksman microcatheter, which was advanced similarly into the left M2, provided the necessary support for the microcatheter to traverse across the ophthalmic segment for distal positioning. d – f A 4.75 × 18 mm Pipeline Flex embolization device was subsequently deployed and the aneurysm was coiled

Article Snippet: This technique has been reported in neurointerventions for vertebral artery origin stenting, or coil embolization of posterior circulation aneurysms in patients with proximal vessel tortuosity.

Techniques: